Taser X3 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Sports et loisirs Taser X3. Taser X3 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 63
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
IMPORTANT SAFETY INSTRUCTIONS.
Read all warnings and instructions in this manual. Save
these instructions.
Models 333200, 33201, 33209, 33210
MMUOO22 Rev: D
TASER
®
X3
ECD
User Manual
Vue de la page 0
1 2 3 4 5 6 ... 62 63

Résumé du contenu

Page 1 - User Manual

IMPORTANT SAFETY INSTRUCTIONS.Read all warnings and instructions in this manual. Save these instructions. Models 333200, 33201, 33209, 33210MMUOO22 Re

Page 2 - Contents

10Up (ARMED)Down (SAFE)Index Finger RestOn each side of the X3 ECD is an ergonomically designed rest upon which to place the tip of your index finger w

Page 3

11flashlight. The EPM will deplete faster in colder weather than warm weather. Likewise, the EPM will deplete faster with the flashlight active. 1 Re

Page 4 - 62 Medical Research

12 4e Remove the protective label from the new EPM. 4f Install the new EPM. Ensure that the EPM is fully inserted into the X3 ECD. Apply sufficient

Page 5 - Warnings

13If no cartridge is loaded in the cartridge bay, the cartridge bay empty icon is displayed.!If something is wrong with the cartridge, the cartridge b

Page 6 - General Information

14!Major Fault indication. A red triangle is probably accompanied by a noticeable failure in the ECD. For example, the flashlight or a laser might not

Page 7 - Common Effects of NMI

15The partial/intermittent circuit completion icon indicates that the connection is marginal.If the connection is not effective, the no circuit comple

Page 8 - Basic X3 Electrical Theory

16Central Information Display (CID) Color Graphic User InterfaceSpark DurationWhen the X3 ECD is deployed with the trigger switch, it delivers an auto

Page 9 - Features & Operation

17!Cartridge Color Indicator (Blast Door) ColorSelected CartridgeSystem Status Indicator – Critical FaultCartridge TypeEnergy Cell Indicator;Fully Cha

Page 10 - Enhanced Power Magazine (EPM)

18Selected CartridgeTraining Mode35-Foot Training CartridgeCartridge Locked60% RemainingOperating Mode (Manual)The CID below shows an X3 ECD in the se

Page 11 - Changing the EPM

19Standard-Range (15'/4 m) LaserFocused Beam LED FlashlightTop LaserLong-Range (35'/10 m) LaserMechanical SightsThe mechanical sights on the

Page 12 - Cartridge Icons

2Contents 5 Chapter 1: Warnings 5 Important Safety and Health Information 5 Use of Force Policy 6 Chapter 2: General Informa

Page 13 - System Status Icons

20Selector SwitchPress the selector switch on the top of the X3 ECD to configure the system. See the "Conguring the X3 ECD" section in this

Page 14 - Circuit Status Icons

21Semi-Automatic ModeWARNINGIn the event of an unintentional discharge, immediately shift the CAM-Lock Safety to the down (SAFE) position to stop the

Page 15 - Operating Mode Icons

223Seconds Elapsed in Cycle (3)Cartridge Energized, ConnectionStatus Good80% RemainingThe Next Cartridge is Selected Automatically when You Remove You

Page 16 - Spark Duration

231The Next Cartridge is Selected Automatically when You Remove Your Finger from the TriggerSeconds Elapsed in Cycle for the Second Deployed Cartridg

Page 17

241Seconds Elapsed in Cycle for the Third Deployed Cartridge (1)80% RemainingAll Three Cartridges Energized,Connection Status Good1Because all three

Page 18 - Top Laser

25you can apply additional cycles to a continually resisting subject, if needed, without deploying any of the remaining cartridges. Holding the ARC sw

Page 19 - Focused Beam LED Flashlight

26 1 Pull the trigger switch to deploy the first cartridge.Deployed CartridgeTwo Remaining, Un-Deployed Cartridges3Seconds Elapsed in Cycle (3)The Se

Page 20 - Ergonomic Grip Design

27 2 Quickly press and release (tap once) the ARC switch to select the second cartridge.ARC SwitchIf the first cycle is still in effect, the CID may l

Page 21 - Semi-Automatic Mode

28 3 Pull the trigger to deploy the second cartridge.Two Deployed CartridgesOne Remaining, Un-Deployed Cartridge1Two Cartridges Energized, Connectio

Page 22

29 4 Press (tap) the ARC switch to select the third cartridge.Arc SwitchIf the previous cycle still is in effect, the CID may look like this: The firs

Page 23

331 Configuring the X3 ECD and Viewing the System Status31 Configuring the Deployment Modes32 Setting the Training Mode33 Configurin

Page 24 - Manual Mode

30 5 Pull the trigger to deploy the third cartridge.Three Deployed Cartridges1Seconds Elapsed in Cycle for the Third Deployed Cartridge (1)80% Rema

Page 25 - Trigger Functions

31Configuring The X3 ECD and Viewing the System StatusWARNINGRemove the Smart Cartridges from the X3 ECD before configuring the ECD or viewing its statu

Page 26

32SYSTEM MENUMODEOFFTRAININGSEMI_AUTOMATICMODE SEMI_AUTOMATIC 8 Press the selector switch to go to the previous menu. You now can configure additiona

Page 27

33SYSTEM MENUMODEOFFTRAININGSEMI_AUTOMATICTRAINING OFFSYSTEM MENUMODEONTRAININGSEMI_AUTOMATICTRAINING ON 9 Press the selector switch to go to the pr

Page 28

34SIGHTING MENUFLASHLIGHTSINGLELASERAUTOMATICFLASHLIGHT AUTOMATICSIGHTING MENUFLASHLIGHTSINGLELASEROFFFLASHLIGHT OFF 7 Press the selector switch to

Page 29

35SIGHTING MENUFLASHLIGHTSINGLELASERONSINGLE Upper Laser On Solid (No Blinking)SIGHTING MENUFLASHLIGHTDUAL 1LASERONDUAL 1 Upper Laser on Solid, Lower

Page 30

36OPTIONS MENUAUTO_SHUTDOWNON 8 Press the selector switch to return to the MAIN MENU. 9 You can set the other options. If you are done configuring

Page 31 - TRAINING

37Configuring The X3 ECD and Viewing the System Status Viewing the EPM InformationTo view information about the EPM, follow these steps: 1 Point the

Page 32 - Setting the Training Mode

38Configuring The X3 ECD and Viewing the System Status Warranty InformationTo view the warranty information, follow these steps: 1 Point the X3 ECD i

Page 33 - Configuring the Flashlight

39Configuring The X3 ECD and Viewing the System Status LanguageTo set the X3 ECD’s language, follow these steps: 1 Point the X3 ECD in a safe directi

Page 34 - OFF Both Lasers are OFF

4Contents61 Chapter 6: Additional Items61 Additional Information61 TASER Training Academy62 Medical Research

Page 35 - Auto Power Down

40Remove the Shipping Cover from the Smart CartridgeSmart Cartridges are shipped with a shipping cover in place. Remove these covers before attempting

Page 36

41 4 Push against this tab while pulling the cartridge out. You might consider pushing on the cartridge with your thumbs and holding the cover with

Page 37 - Viewing the EPM Information

42Selecting CartridgesBy default, the leftmost active cartridge is selected. Whether your X3 ECD is set up for the semi-automatic or manual deployment

Page 38 - Warranty Information

43Standard-Range (15 ft/4 m and 25 ft/7 m) TASER X3 Smart CartridgesBlast DoorsBOTTOM PROBE POINTS 7 DOWNoLong-Range (35 ft/10 m) TASER X3 Smart Car

Page 39 - Language

44The X3 ECD can determine whether the Smart Cartridges loaded in the cartridge bays have been expended or not. The ECD also can determine whether all

Page 40

45Load the Smart CartridgesWARNINGNever place your hands or fingers in front of the cartridge. When loading and unloading, always hold the cartridge on

Page 41

46Loaded X3 ECD viewed at an angle.Load the Smart CartridgesLoadingSmart Cartridges are shipped with a shipping cover in place. Remove these covers be

Page 42 - Selecting Cartridges

47 5 Verify that the cartridge is secure by pulling on the tabs on the lower and upper part of the cartridge.As shown in the illustrations, the left

Page 43 - BOTTOM PROBE POINTS 7 DOWN

48Load the Smart CartridgesUnloading 1 Point the ECD in a safe direction. 2 Ensure the CAM-Lock Safety is in the down (SAFE) position. 3 Keep yo

Page 44 - Training/Locked/Training

49Aiming and Probe PlacementHold Level Don't TiltAll TASER ECD deployments should be in accordance with department policies and procedures. Norma

Page 45 - Load the Smart Cartridges

5Important Safety and Health InformationRead, understand and follow the product warnings and safety instructions contained in the Product Warnings doc

Page 46

50The top probe impacts the target near the top laser beam but exact placement can vary depending on distance, type of cartridge, etc.Hold the X3 ECD

Page 47 - Cartridge Release Button

51Although you can use a Warning Arc display when the ECD is unloaded, it is recommended that you always arc display with the cartridges installed. Th

Page 48 - Charge Diffusion™ Probes

52Drive-Stun Backup Drive-stun capability is available with the X3 ECD. To apply a drive-stun, place the safety in the up (ARMED) position and press t

Page 49 - Preferred Target Zones

53Drive-Stun BackupRecommended Drive-Stun Areas for Maximum Effect When officer safety is at risk, drive the X3 ECD into the following areas for maximum

Page 50 - Warning Arc™ Display

54Spark TestTASER International recommends conducting a spark test every 24 hours or prior to the start of your shift for your individually issued X3

Page 51 - Electrodes

55Chapter 4 Maintenance/TroubleshootingWhat to Do Following ECD UseConsiderations for Handling Used ProbesEach agency will establish its own proce

Page 52 - Drive-Stun Backup

56Uploading Firmware Revisions The X3 ECD internal firmware provides functionality for all aspects of the ECD. The firmware can be upgraded to the most

Page 53

57TASER Online Troubleshooting GuideA troubleshooting guide is available by visiting EVIDENCE.COM. If you need product support on accessories or have

Page 54 - Maintenance/Troubleshooting

58The Event Log also stores System Configuration Change Events. This is any time a system configuration is changed. For example, if the date, time, lang

Page 55 - Police/Military K-9 Caution

59The deployment log includes the following information for the most recent 1,500+ discharges:• Date, time, and duration of each discharge in both GM

Page 56 - Dropped or Wet X3 ECD

6What is the X3 ECD?The TASER X3 ECD is a software upgradable, 3-shot ECD manufactured by TASER International, Inc. ECDs use propelled wires or direct

Page 57 - Event Log

60Magnesium Transporter HolsterThe TASER X3 ECD comes standard with a Magnesium Transporter Holster optimized to provide maximum security and reliabil

Page 58 - Dataport Download Kit

61Additional Information New TASER brand products are under development. Visit our Web site at www.TASER.com for the latest information. Material Safe

Page 59 - USB Connection Status

62• TASER Master Instructor Course • TASER Technician Course • TASER Evidence Collection and Analysis Course• TASER Use of Force, Risk Management

Page 60 - Optional Accessories

AXON, Charge Diffusion, Engineering Log, Event Log, EVIDENCE.COM, Precision Shaped Pulse, Pulse Log, Rotational-Pulse Drive, Smart Cartridge, TACOM, TP

Page 61 - Additional Items

7Neuro Muscular Incapacitation (NMI)The human nervous system communicates with simple electrical impulses. The command center (brain and spinal cord)

Page 62 - Medical Research

8• Yelling or screaming;• Involuntary strong muscle contractions;• Freezing in place with legs locked;• Dazed feeling for several seconds or minut

Page 63 - MMUOO22 Rev: D

9X3 ECD and Cartridge FeaturesGet to know the X3 ECD:Bottom LaserBlast DoorSelector SwitchTrigger SwitchIndex Finger RestCAM-Lock SafetyEPMARC SwitchL

Commentaires sur ces manuels

Pas de commentaire